Inversor solar MUST PV2900 HP do catálogo 2026
MUST EnergySolução durável
Inversores de 220 VMUST

PV2900 HP

Inversor solar MUST PV2900 HP da linha 2026, com potência de 1–6 kW e saída CA de 220/230/240 V. Consulte a ficha completa para comparar modelos, proteções, comunicação, dados elétricos e dimensões.

Potência1–6 kW
Saída CA220/230/240 V
Bateria12/24/48 V CC
MPPT80 A

Principais parâmetros da série

PARÂMETROS PRINCIPAIS
MODELOPV29-1012
HP
PV29-1024
HP
PV29-1512
HP
PV29-1524
HP
PV29-2012
HP
PV29-2024
HP
PV29-3024
HP
PV29-3048
HP
PV29-4024
HP
PV29-4048
HP
PV29-5048
HP
PV29-6048
HP
Nominal Battery System Voltage12VDC24VDC12VDC24VDC12VDC24VDC24VDC48VDC24VDC48VDC48VDC48VDC
SAÍDA DO INVERSOR
Rated Power1 KW1.5 KW2 KW3 KW4 KW5 KW6 KW
Surge Rating3000VA4500VA6000VA9000VA12000VA15000VA18000VA
Capable Of Starting Electric Motor1P1P1.5P2P3P
Nominal Output Voltage RMS220V / 230V / 240VAC (±10% RMS)
Inverter Efficiency (Peak)
Line Mode Efficiency
>88%
>95%
Power Factor1.0
Typical Transfer Time10ms(max)
Overload100% < Load < 110% (alarm 5min then stop output and fault code 07)
110% < Load < 125% (alarm 60s then stop output and fault code 07)
Load > 125% (alarm 10s then stop output and fault code 07)
ENTRADA CA
Voltage230VAC
Selectable Voltage Range155~265VAC(For personal computers)
Frequency Range50Hz / 60Hz(Auto sensing) 40~80Hz
BATERIA
Minimum Start Voltage(10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Voltage Alarm(10V / 10.5V / 11V / 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Voltage Cut Off10V / 10.5V / 11V / 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Alarm(12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover(12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Energy Saving ModeLoad ≤50±20W(120V)/100±20W(220V)
CARREGADOR
Output VoltageDepends on battery type
Overcharge Protection S.D.15.5VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
Maximum Charge Current30A20A45A25A60A30A40A20A60A30A35A40A
PAYPASS & PROTECTION
Input Voltage WaveformSine wave (grid or generator)
Nominal Input Frequency50Hz or 60Hz
Overload Protection (SMPS Load)Circuit breaker
Output Short Circuit ProtectionCircuit breaker
AC Input Breaker1-3K/30A4-6K/50A
CARREGADOR SOLAR
Maximum PV Array Power1250W2500W1250W2500W1250W2500W2500W5000W2500W5000W5000W5000W
Maximum PV Charge Current80A±4A
DC Voltage12V/24V/48V auto work
MPPT Range
@ Operating Voltage
15~95VDC@12V/ 30~230VDC@24V/ 60~230VDC@48V
Maximum PV Array
Open Circuit Voltage
245VDC
Standby Power Consumption<2W
OUTROS PARÂMETROS
MODELOPV29-1012
HP
PV29-1024
HP
PV29-1512
HP
PV29-1524
HP
PV29-2012
HP
PV29-2024
HP
PV29-3024
HP
PV29-3048
HP
PV29-4024
HP
PV29-4048
HP
PV29-5048
HP
PV29-6048
HP
ESPECIFICAÇÕES MECÂNICAS
Machine Dimension(W*H*D) (mm)309*460*196309*545*200
Package Dimensions(W*H*D)(mm)610*310*400695*310*400
N.W (kg)//
G.W (kg)//
OUTROS
Operating Temperature Range0°C ~ 40°C
Storage Temperature-15°C ~ 60°C
Audible Noise60dB MAX
DisplayLED+LCD
Standard Warranty2 year
CERTIFICAÇÕES E NORMAS
CE-EMC+LVD (EN6100-6-3:2007, EN6100-6-1:2017+EN IEC62109-1:2010, EN IEC62109-2:2011)

O preço depende do modelo e da configuração.